| Accuracy ± (0.1% of span) |
|
|
|
| FB400 Process / Temperature Controller |

A catalog download is here.
FB_01E.pdf (871KB)
(FB series)
Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current |
| Sampling time |
0.1 sec.
0.05 sec. / 0.25 sec. is selectable. |
| Measuring accuracy |
Thermocouple : K, J, T, E, PLII
Less than -100°C : ±1.0°C
-100 to 500°C : ±0.5°C
More than 500°C : ±(0.1% of reading + 1 digit)
Thermocouple : N, S, R, W5Re/W26Re
Less than -100°C : ±2.0°C
-100 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
Thermocouple : B
Less than 400°C : ±70.0°C
400 to 1000°C : ±(1.4°C + 1 digit)
More than 1000°C : ±(0.1% of reading + 1 digit)
RTD
Less than 200°C : ±0.2°C
More than 200°C : ±(0.1% of reading + 1 digit)
DC voltage and DC current
±(0.1% of span) |
| Cold junction temperature compensation error |
±1.0°C (between 5 to 40°C)
With in ±1.5°C
(between -10 to +5°C , between 40 to 50°C) |
| Control method |
Brilliant II PID control
(with autotuning and startup tuning)
Brilliant II PID control Heat/Cool type
(with autotuning)
Position proportioning control l without feedback resistance (with autotuning) |
| Control output type |
Relay contact output
Voltage pulse output
DC current output
DC voltage output
SSR (Triac) output
Open collector output (Sink type) |
| Communications |
Communication 1
RS-232C
RS-422A
RS-485
* MODBUS
Communication 2 (Inter-controller communication)
RS-485 |
| External Dimensions |
48 x 96 x 60mm (W x H x D) |
| Standard function |
Memory area : 8 areas
Digital input : 3 points (Mode selection)
Remote setpoint input
Waterproof/Dustproof : NEMA4X, IP66
(Waterproof/Dustproof protection only effective from the front in panel
mounted installation.) |
| Optional function |
Ivent (alarm) output : Max. 4 points
Digital input : 4 points (Memory area selection + Area set)
Heater break alarm
Analog retransmission output : 1 point
Position resistance input
Power feed forward function |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| HA400 Process / Temperature Controller |

A catalog download is here.
HA_01E.pdf(533KB)
(HA series)
Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current
* Number of inputs : 2 points |
| Sampling time |
0.025 sec. |
| Measuring accuracy |
Thermocouple : K, J, T, E, PLII
Less than -100°C : ±1.0°C
-100 to 500°C : ±0.5°C
More than 500°C : ±(0.1% of reading + 1 digit)
Thermocouple : N, S, R, W5Re/W26Re
Less than -100°C : ±2.0°C
-100 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
Thermocouple : B
Less than 400°C : ±70.0°C
400 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
RTD
Less than 200°C : ±0.2°C
More than 200°C : ±(0.1% of reading + 1 digit)
DC voltage and DC current
±(0.1% of span) |
| Cold junction temperature compensation error |
±1.0°C (at 23°C ± 2°C)
±1.5°C (between 0 to 50°C) |
| Control method |
Brilliant PID control (with enhanced autotuning)
Position proportioning control |
| Control output type |
Relay contact output
Voltage pulse output
DC current output
DC voltage output |
| Communications |
Number of communications : 2 points
RS-232C
RS-422A
RS-485
* MODBUS, DeviceNet, Profibus supported. |
| External Dimensions |
48 x 96 x 100mm (W x H x D) |
| Standard function |
Memory area : 16 areas
Cascade control (only 2 channel type) |
| Optional function |
Ivent (alarm) output : Max. 4 points
Ivent input : 7 points
Remote set value function
Heater break alarm
Analog retransmission output : 3 points
Position feedback resistance input
(Position proportioning control)
Power feed forward function
Waterproof/Dustproof : IP65 |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| FB900 Process / Temperature Controller |

A catalog download is here.
FB_01E.pdf (871KB)
(FB series)
Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current |
| Sampling time |
0.1 sec.
0.05 sec. / 0.25 sec. is selectable. |
| Measuring accuracy |
Thermocouple : K, J, T, E, PLII
Less than -100°C : ±1.0°C
-100 to 500°C : ±0.5°C
More than 500°C : ±(0.1% of reading + 1 digit)
Thermocouple : N, S, R, W5Re/W26Re
Less than -100°C : ±2.0°C
-100 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
Thermocouple : B
Less than 400°C : ±70.0°C
400 to 1000°C : ±(1.4°C + 1 digit)
More than 1000°C : ±(0.1% of reading + 1 digit)
RTD
Less than 200°C : ±0.2°C
More than 200°C : ±(0.1% of reading + 1 digit)
DC voltage and DC current
±(0.1% of span) |
| Cold junction temperature compensation error |
±1.0°C (between 5 to 40°C)
With in ±1.5°C
(between -10 to +5°C , between 40 to 50°C) |
| Control method |
Brilliant II PID control
(with autotuning and startup tuning)
Brilliant II PID control Heat/Cool type
(with autotuning)
Position proportioning control l without feedback resistance (with autotuning) |
| Control output type |
Relay contact output
Voltage pulse output
DC current output
DC voltage output
SSR (Triac) output
Open collector output (Sink type) |
| Communications |
Communication 1
RS-232C
RS-422A
RS-485
* MODBUS
Communication 2 (Inter-controller communication)
RS-485 |
| External Dimensions |
96 x 96 x 60mm (W x H x D) |
| Standard function |
Memory area : 8 areas
Digital input : 3 points (Mode selection)
Remote setpoint input
Waterproof/Dustproof : NEMA4X, IP66
(Waterproof/Dustproof protection only effective from the front in panel
mounted installation.) |
| Optional function |
Ivent (alarm) output : Max. 4 points
Digital input : 4 points (Memory area selection + Area set)
Heater break alarm
Analog retransmission output : 1 point
Position resistance input
Power feed forward function |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
| HA900 Process / Temperature Controller |

A catalog download is here.
HA_01E.pdf(533KB)
(HA series)
Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required. |
| Input |
Thermocouple, RTD, DC voltage, DC current
* Number of inputs : 2 points |
| Sampling time |
0.25 sec. |
| Measuring accuracy |
Thermocouple : K, J, T, E, PLII
Less than -100°C : ±1.0°C
-100 to 500°C : ±0.5°C
More than 500°C : ±(0.1% of reading + 1 digit)
Thermocouple : N, S, R, W5Re/W26Re
Less than -100°C : ±2.0°C
-100 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
Thermocouple : B
Less than 400°C : ±70.0°C
400 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)
RTD
Less than 200°C : ±0.2°C
More than 200°C : ±(0.1% of reading + 1 digit)
DC voltage and DC current
±(0.1% of span) |
| Cold junction temperature compensation error |
±1.0°C ( at 23°C ± 2°C )
±1.5°C ( between 0 to 50°C ) |
| Control method |
Brilliant PID control (with enhanced autotuning)
Position proportioning control |
| Control output type |
Relay contact output
Voltage pulse output
DC current output
DC voltage output |
| Communications |
Number of communications : 2 points
RS-232C
RS-422A
RS-485
* MODBUS, DeviceNet, Profibus supported. |
| External Dimensions |
96 x 96 x 100mm ( W x H x D ) |
| Standard function |
Memory area : 16 areas
Cascade control ( only 2 channel type ) |
| Optional function |
Ivent (alarm) output : Max. 4 points
Ivent input : 7 points
Remote set value function
Heater break alarm
Analog retransmission output : 3 points
Position feedback resistance input
(Position proportioning control)
Power feed forward function
Waterproof/Dustproof : IP65 |
|
| Go to "Quick Reference Guide" Index Page. |
|
| Go to Page Top |
|
 |
 |
RKC INSTRUMENT INC. |
|
|
|